Recirculating Chiller

This category lists 24 sealed recirculating chiller models, led by the DLSB series, with tank capacities from 5 L to 100 L and cooling temperatures of -30 °C and -40 °C. A recirculating chiller supplies closed-loop coolant to condensers on rotary evaporators, glass reactor jackets, and other laboratory chiller duties where tap water cannot hold temperature. Compare DLSB-5-30 through DLSB-100-40 below, or pair one with a heating and cooling integrated machine for processes that alternate between heating and chilling.

Recirculating Chiller from UnionClay for recirculating chiller buyers. Compare models, applications, selection guidance, FAQ and related equipment for quo.

Recirculating Chiller Selection Guide

UnionClay Recirculating Chiller pages are built for procurement teams comparing recirculating chiller options with model-level product pages, related equipment and quotation support. This category is relevant for buyers matching cooling capacity, target temperature and pump circulation for reactors, condensers and evaporators.

Common search and AI-discovery terms for this category include recirculating chiller, laboratory chiller, cooling circulator, low temperature recirculating chiller. Use this hub to compare models, confirm process fit and move from product browsing to equipment matching.

Applications

  • reactor cooling
  • rotary evaporator condenser cooling
  • molecular distillation condenser support
  • laboratory process cooling

How to Choose Recirculating Chiller

Start with the working capacity, target temperature or vacuum condition, medium compatibility, connection size, voltage, control requirements and the equipment already in the process line. For quote-first procurement, share process details so UnionClay can recommend a model and matching support equipment.

Featured Models in This Category

Related Equipment Hubs

FAQ

What information should I provide before requesting a quote?

Send the target capacity, working medium, temperature range or vacuum requirement, voltage, connection size, application and any customization needs.

Can UnionClay match this category with other process equipment?

Yes. UnionClay can match reactors, chillers, heating and cooling circulators, vacuum pumps, filtration equipment, rotary evaporators, distillation systems and related support equipment according to the workflow.

Is the content on this category based on real product material?

UnionClay source materials include DLSB sealed and non-sealed recirculating chiller models for low-temperature coolant circulation.

Recirculating Chiller Full-Series Specification Comparison

Every DLSB recirculating chiller in this category sits in one comparison table below: sealed and non-sealed builds, -30℃ and -40℃ low-temperature limits, published power draw, coolant tank or reservoir volume and pump circulation data, each model linked to its full product page.

ModelBuildTemperature rangeVoltageTotal powerCoolant tank / reservoirPump flow / head
DLSB-50-40 Sealed Recirculating ChillerSealed-40℃ to room temperature380V,50Hz4.6KW17L expansion tank20 L/min / 20 m
DLSB-50-30 Sealed Recirculating ChillerSealed-30℃ to room temperature380V,50Hz4KW17L expansion tank20 L/min / 20 m
DLSB-5-40 Sealed Recirculating ChillerSealed-40℃ to room temperature220V,50Hz1KW2L expansion tank20 L/min / 20 m
DLSB-5-30 Sealed Recirculating ChillerSealed-30℃ to room temperature220V,50Hz0.9KW2L expansion tank20 L/min / 20 m
DLSB-30-40 Sealed Recirculating ChillerSealed-40℃ to room temperature380V,50Hz3.3KW10L expansion tank20 L/min / 20 m
DLSB-30-30 Sealed Recirculating ChillerSealed-30℃ to room temperature220V,50Hz1.7KW10L expansion tank20 L/min / 20 m
DLSB-20-40 Sealed Recirculating ChillerSealed-40℃ to room temperature380V,50Hz2.5KW10L expansion tank20 L/min / 20 m
DLSB-20-30 Sealed Recirculating ChillerSealed-30℃ to room temperature220V,50Hz1.4KW7L expansion tank20 L/min / 20 m
DLSB-100-40 Sealed Recirculating ChillerSealed-40℃ to room temperature380V,50Hz5.7KW35L expansion tank45 L/min / 25 m
DLSB-100-30 Sealed Recirculating ChillerSealed-30℃ to room temperature380V,50Hz4.8KW35L expansion tank45 L/min / 25 m
DLSB-10-40 Sealed Recirculating ChillerSealed-40℃ to room temperature220V,50Hz1.4KW7L expansion tank20 L/min / 20 m
DLSB-10-30 Sealed Recirculating ChillerSealed-30℃ to room temperature220V,50Hz1KW7L expansion tank20 L/min / 20 m
DLSB-50-40 Non-sealed Recirculating ChillerNon-sealed-40℃ to room temperature380V,50Hz4.5KW50L reservoir60 L/min / 6 m
DLSB-50-30 Non-sealed Recirculating ChillerNon-sealed-30℃ to room temperature380V,50Hz4KW50L reservoir60 L/min / 6 m
DLSB-5-40 Non-sealed Recirculating ChillerNon-sealed-40℃ to room temperature220V,50Hz0.9KW5L reservoir10 L/min / 7 m
DLSB-5-30 Non-sealed Recirculating ChillerNon-sealed-30℃ to room temperature220V,50Hz0.58KW5L reservoir10 L/min / 7 m
DLSB-30-40 Non-sealed Recirculating ChillerNon-sealed-40℃ to room temperature380V,50Hz3.2KW30L reservoir15 L/min / 8 m
DLSB-30-30 Non-sealed Recirculating ChillerNon-sealed-30℃ to room temperature220V,50Hz1.8KW30L reservoir15 L/min / 8 m
DLSB-20-40 Non-sealed Recirculating ChillerNon-sealed-40℃ to room temperature380V,50Hz2.5KW20L reservoir15 L/min / 8 m
DLSB-20-30 Non-sealed Recirculating ChillerNon-sealed-30℃ to room temperature220V,50Hz1.3KW20L reservoir15 L/min / 8 m
DLSB-100-40 Non-sealed Recirculating ChillerNon-sealed-40℃ to room temperature380V,50Hz4.8KW100L reservoir35 L/min / 11 m
DLSB-100-30 Non-sealed Recirculating ChillerNon-sealed-30℃ to room temperature380V,50Hz4.8KW100L reservoir35 L/min / 11 m
DLSB-10-40 Non-sealed Recirculating ChillerNon-sealed-40℃ to room temperature220V,50Hz1.2KW10L reservoir15 L/min / 8 m
DLSB-10-30 Non-sealed Recirculating ChillerNon-sealed-30℃ to room temperature220V,50Hz0.85KW10L reservoir15 L/min / 8 m
Low Temperature Recirculating Chiller

Values are aggregated from the specification tables and parameter sheets published on each UnionClay product page. A dash means the page does not publish that value. Complete parameters, safety protection data and connector details are on each linked product page.

Series snapshot from the table: 25 pages — 12 sealed models, 12 non-sealed models and one family overview. Low-temperature limits -30℃ and -40℃ on every frame. Published power runs 0.58KW to 5.7KW on 220V or 380V, 50Hz. Sealed expansion tanks span 2L to 35L; open reservoirs span 5L to 100L. Pump data runs 20-45 L/min at 20-25 m head on sealed builds and 10-60 L/min at 6-11 m head on non-sealed builds, and every published sheet lists a PT100 temperature sensor.

How to Choose Within the DLSB Series

The model code carries most of the answer. The first number is the frame class — on non-sealed units it equals the open reservoir volume in liters, so a DLSB-10 carries a 10L reservoir and a DLSB-100 a 100L one. The second number is the low-temperature limit, -30 or -40. Decide the temperature limit first, then the frame class, then read the voltage column before anything goes on a shortlist: small frames run 220V,50Hz while the larger frames and most -40 builds need a 380V supply. That one pass removes most wrong candidates before any cooling-load calculation starts.

  • Sealed against non-sealed

    Sealed builds circulate through a closed expansion tank — 2L to 35L across the table — and keep the coolant away from open air. Non-sealed builds use an open 5L to 100L reservoir that is simpler to top up and inspect. If coolant exposure or condensation matters in your lab, start from the sealed half of the table.

  • -30℃ against -40℃

    Both limits exist for every frame, and the -30 variant consistently draws less power at the same size: 4KW against 4.6KW at DLSB-50, 0.9KW against 1KW at DLSB-5 in the sealed line. If the condenser or jacket load is comfortable at -30℃, buying -40℃ as insurance mostly buys a higher power draw.

  • Pump flow and head

    Sealed frames publish 20 to 45 L/min flow with 20 to 25 m head; non-sealed frames publish 10 to 60 L/min with 6 to 11 m head. Long coolant lines, narrow condenser coils and height differences consume head quickly — when the chiller sits far from the equipment it serves, read the pump column before the temperature column.

  • Voltage and utilities

    220V,50Hz covers the small frames. Every sealed -40 build from DLSB-20-40 upward and all 100L-class units run 380V,50Hz. Confirm the supply at the installation point first — a 380V machine facing a 220V-only lab is the most avoidable mismatch in this table.

Worked read of the table: a 30L-class duty that must hold -35℃ starts in the -40 column, which leaves two candidates — DLSB-30-40 sealed (380V, 3.3KW, 10L expansion tank, 20 L/min at 20 m) and DLSB-30-40 non-sealed (380V, 3.2KW, 30L reservoir, 15 L/min at 8 m). Same frame, same limit; the decision collapses to tank build and pump head. That is the intended reading order: cut by temperature, cut by frame, let the last two columns decide.

Frame-by-Frame Notes from the Published Tables

  • 5 and 10-class frames

    The entry frames stay on 220V,50Hz across both builds and both temperature limits. Sealed tanks run 2L on the 5-class and 7L on the 10-class; non-sealed reservoirs run 5L and 10L. Published power spans 0.58KW on the DLSB-5-30 non-sealed up to 1.4KW — bench condensers and small jacketed vessels are the natural duty here.

  • 20 and 30-class frames

    This is where the voltage split starts: the -40 builds move to 380V,50Hz while the -30 builds stay on 220V in both lines. Sealed tanks hold 7L to 10L, non-sealed reservoirs 20L to 30L, and power runs 1.3KW to 3.3KW. If the site has no 380V supply, the -30 variants are the practical ceiling of this pair.

  • 50-class frames

    All four 50-class pages publish 380V,50Hz at 4KW to 4.6KW. The pump contrast is the sharpest in the whole table: the sealed build lists 20 L/min at 20 m head, the non-sealed lists 60 L/min at 6 m head — one favors lift over distance, the other favors volume through short fat lines. Pick by the loop, not by habit.

  • 100-class frames

    The largest published frames pair a 35L expansion tank (sealed) or a 100L open reservoir (non-sealed) with 4.8KW to 5.7KW draw, all on 380V. Pump data flips against the 50-class: 45 L/min at 25 m head sealed, 35 L/min at 11 m head non-sealed — worth a second read if the install spans floors.

Where These Chillers Sit in a Process Line

In a working line these chillers hold the cold side of four jobs this catalog already maps: reactor jacket cooling, rotary evaporator condenser cooling, molecular distillation condenser support and general laboratory process cooling. The frame class follows the heat load of that connected equipment — which is why the quote checklist below asks about the equipment served before anything else.

What these pages do not publish, by design: cooling capacity at specific temperature points and a recommended coolant medium. Both depend on the working condition, so ask for them in the quotation instead of estimating from the power column — total power is electrical draw, not cooling duty.

Mistakes This Table Is Built to Prevent

  • Sizing by tank volume

    The tank and reservoir column describes coolant holding, not cooling duty. Two machines with the same 10L figure can sit in different frames with different power draw — size from the equipment served and the temperature limit, then confirm duty at quotation.

  • Assuming the lab supply fits

    Half this table runs 380V,50Hz. Ordering a 380V frame into a 220V-only room is the classic avoidable rework — the voltage column exists so that conversation happens before the purchase order, not after delivery.

  • Ignoring pump head until installation

    Head spans 6 m to 25 m across the table. A chiller that holds temperature perfectly but cannot push coolant up to a mezzanine condenser is still the wrong chiller — read flow and head against the real line routing.

  • Defaulting to -40℃ for safety

    The -30 variant of every frame draws less published power for the same circulation. If the process never goes below -25℃, the -40 column is paying for margin the table already shows is unnecessary.

Quote Checklist for This Category

A quotation moves fastest when the inquiry already answers the columns above:

  • Target temperature at the condenser or jacket — decides -30 against -40
  • The equipment served (reactor volume, evaporator size or condenser type) — decides the frame class
  • Voltage available at the installation point — 220V or 380V per the table
  • Coolant line length and height difference — read against the pump flow / head column
  • Sealed or non-sealed preference, with any coolant exposure rules in the lab
  • Cooling capacity requirement at the working temperature — the value the pages leave to quotation

Selection FAQ

Sealed or non-sealed recirculating chiller — which one should I shortlist?

Sealed DLSB builds run a closed loop with a 2L to 35L expansion tank, which suits processes that want minimal coolant exposure. Non-sealed builds carry open 5L to 100L reservoirs that are easier to refill and inspect. Exposure and maintenance habits usually settle this faster than any other criterion — the Build column in the table separates the two lines.

How do I read DLSB model numbers like DLSB-50-40?

The first number is the frame class — it matches the reservoir volume in liters on non-sealed units — and the second number is the low-temperature limit in degrees below zero. DLSB-50-40 is the 50-class frame reaching -40℃; DLSB-50-30 is the same frame limited to -30℃ with a lower published power draw.

Which DLSB chillers run on 220V power?

The table shows 220V,50Hz on the smaller frames — DLSB-5 and DLSB-10 in both builds plus several -30 variants up to the 30-class. The larger frames and most -40 builds list 380V,50Hz. Match the voltage column against the installation site before requesting a quote.

Related Equipment and Quotation Support

A chiller is rarely bought alone. These hubs cover the equipment that usually shares the same purchase order, and the UnionClay team matches models across categories from one inquiry.